D-R220 is a Optical dust and opacity meter. Monitoring dust emissions on smaller plants and in process applications.

FEATURES

  • In-situ measurement directly in the flue gas
    flow
  • Digital operation with microprocessor
  • Adjustable limit value
  • 2 contact switch outputs
  • Measuring value integral 4/15/64 seconds
  • Internal event memory
  • PC-interface for easy maintenance
  • Modbus RTU interface
  • Measurement results shown as opacity or extinction
  • No weather protection covers needed

SPECIFICATION

Measurements opacity, extinction accuracy <2% of measuring range
Measuring ranges 0–25/50/100% OP
0–0.2 / 0.4-1.6 Ext
0-160 mg/m3
0-4000 mg/m3 1) dust
detection limit <2% of measuring range
Measuring principle transmission supply voltage 24 VDC, 0.4 A
Flue gas temperature above dew point up to 200°C, optional up to 500°C, depending on application dimensions
(h × w × d)
measuring head
160 × 150 × 314 mm
Flue gas pressure -50 up to +10 hPa, optional higher weight measuring unit 2.7 kg, reflector 1.6 kg
Duct diameter 400–10,000 mm Supply box
Ambient temperature -20 up to +50°C purge air supply integrated
Protection IP65 supply voltage 85–264 VAC, 46–63 Hz, 50 VA
Measuring outputs 0/4–20 mA / 400 Ohm dimensions
(h × w × d)
210 × 300 × 380 mm
Digital outputs 2 relay outputs 30 VA, max. 48 V / 0.5A weight 13 kg
protection IP54
Remarks 1) with reference to one meter of path length after gravimetric calibration